SRD FAQ #17

FAQ Index

Is it possible to disable the resistivity monitor on 101 controllers?



Wafer flux is rinsed off after reflow, and the flux clogs the resistivity sensor.

There are two options:
1.The 101 controller
e-Prom, can programmed to disable the resistivity monitor function.
(The current e-Prom code is needed).

semiconductor controller parts equipment 101 controller


2. Change 101 controller
"Q-RINSE" set point to 0. As long as the resistivity probe, located on the back of the SRD, is connected there will not be a "resistivity error" prompt.

semiconductor parts equipment 101 controller

Still have questions? Contact Rhetech Customer Service

Rhetech, Inc. 416 South 4th Street, Coopersburg, PA 18036-2039, Phone 610.282.0105, FAX: 610.282.0789
©2008 All Rights Reserved. Rhetech, Inc.