101 CONTROLLER SHOWS "BAD PARAMETERS" / RESETTING CONTROLLER

 

After powering up, the controller displays "BAD PARAMETERS". This message indicates a recipe checksum error has occurred.

The following procedure Erases all Recipes.
(This procedure can be performed with the controller connected or disconected to the SRD).

  • This procedure can be performed with the controller connected to the SRD or on a bench.
  • Remove controller lid and lift the power supply tray
  • Turn on controller power switch.
  • Depress both Memory Clear Buttons.
    (SW1 and SW2 buttons located on the main logic board, see photo below).
  • Release SW1 first (SW1 switch located on left), then release SW2 (located in the middle).
  • If the error does not clear, contact Rhetech Customer Service
 
 

Still have questions? Contact Rhetech Customer Service

Rhetech, Inc. 416 South 4th Street, Coopersburg, PA 18036-2039, Phone 610.282.0105, FAX: 610.282.0789