SRD FAQ #24

FAQ Index

Warning : N2 heater/manifold bracket can be improperly installed

 

The N2 heater manifold bracket can be improperly installed during customer maintenance and filter changes.

Rhetech strongly recommends that all SRD owners perform the preventative maintenance outlined in their tool manuals.

The Spin Rinser Dryer manuals outline monthly preventative maintenance inspections of all bowl attachments including the N2 heater manifold.

(Sections 2.2.1 in 101 and 3.1 in 102 manual)

SRD w/101 Controller- Updated Manual Page
SRD w/102 Controller Manual Updated Page

 

N2 Manifold Physical Inspection:

Grasp each end of the manifold tube between thumb and forefinger and lift up on the manifold.

Any play or movement indicates either the manifold is not properly bolted on, or a weld has broken.

N2 manifolds with broken welds should be replaced; loose manifolds should be tightened to OEM specs.

(Torque to 6 in/lbs).

semiconductor parts and equipment n2 heater manifold

N2 Heater Mounting Bracket

N2 Manifold Inspection

The PM technician should replace any N2 manifolds screwed down flush against the SRD bowl. (See photo left)

(Over tightened bracket nuts can weaken the welds damaging the N2 manifold resulting in particle contamination issues).

N2 manifold
/heater replacement instructions

Still have questions? Contact Rhetech Customer Service

Rhetech, Inc. 416 South 4th Street, Coopersburg, PA 18036-2039, Phone 610.282.0105, FAX: 610.282.0789