25-28 dynamic PSI is a basic N2 setting
for good particle performance for SRDs
equiped with ferro-fluidic seals.
(For SRDs with GPS-Gas Pressurized Seals,
30-35 dynamic PSI is recomended)
| |
| Depending
on the dynamics of the bowl and N2 manifold, adjusting the N2 pressure slightly
higher or lower will result in better particle performance. |